Pxie-4144. PXIe-4139 in LabVIEW. Pxie-4144

 
PXIe-4139 in LabVIEWPxie-4144  Voltage Programming and Measurement Accuracy/Resolution Range Resolution (noise limited)

You can use the VST to test a variety of cellular and wireless standards such as Wi-Fi 6 and 5G NR. Description. Caution The protection provided by this product may be impaired if it is used in aThe PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Although the exact settings can vary, this issue is usually unlikely to be noticed during normal use. Refer to the NI website for an up-to-date list of known issues in NI-DCPower 18. The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. com. FIM card MOOG — D136-001-007 Servo valve, controller, module NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module,. referred to collectively as PXIe-414x SMUs. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. 8 in. 15 days free replacement for quality problemsni pxie-4144/4145のすべてのチャンネルは過電流の状況から保護されています。この状況によって保護回路が作動し、関連するチャンネルの出力を無効にして出力コネクタピンからチャンネル回路の接続を切断します。出力接続を内部的に解除することで、ni pxie-4144/4145と検査対象デバイスの両方を. This page documents all the applicable standards and certifications for the PXIe-4144 and provides downloadable certifications. We have 2 National Instruments NI PXIe-4081 manuals available for free PDF download: Calibration Procedure, Getting Started Manual National Instruments NI PXIe-4081 Calibration Procedure (28 pages) PXIe, 6 1/2-Digit, +/-300 V, Onboard 1. 99 oz) Front panel connectors 25-position D-SUB, male Power Requirement PXI Express power requirement 600 mA from the 12 V rail and 350 mA from the 3. Reported Version: NI-DCPower 21. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. 4. National Instruments PXIe-4137 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. Please select your country. 4Channels PXIe-4144 Current/Voltage Measure, Current/Voltage. Part Number: 782435-01. edited. PXIe-4144; PXIe-4145; Known Issues. 0 cm × 13. The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. Refer the NI DC Power Supplies and SMUs Help for more information about. 2. Remove any front panel connections from the NI 414x. PXIe-4144 PXIe-4141 PXIe-4145 PXIe-4140 PXIe-4143 PXIe-4154 Driver. PXIe-4144. Why can't I use the Source Delay to wait for my output to. 7. For your reference I. NI. 6. The digitizer functionality of NI SMUs is essential for capturing detailed transient characteristics of the SMU response or for characterizing device under test (DUT) behavior such as line. 2255 Contact US. Diversified models and products, and all kinds of rare and discontinued products 4. Dimensions 3U, one-slot, PXI Express/CompactPCI Express module 2. PXIe-4144 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 解决方案. Pizazz Pizza Victoria - Hours & Reviews - 4144 Wilkinson Road. Using the LabVIEW Instrument Design Libraries for Reconfigurable Oscilloscopes and. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. Surprisingly I cannot fund how the sample acquisition rate can be set with this package. 3 V rail Environment Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature) Pollution Degree 2 Indoor use only. Device-specific information about these modules is included in the NI DC Power Supplies and SMUs Help. Caution Limit DC power sinking to 12 W. PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, PXIe-4145 , and PXIe-4147 SMUs, which are referred to collectively as PXIe-414x SMUs. MODULE ASSEMBLY,PXIE-4144. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 1024 x 768 screen resolution (1366 x 768 or higher recommended) InstrumentStudio 2020 supports the following operating systems: Windows 7 (SP1) 64-bit. Other Support Options Ask the NI Community. 4 | ni. PXIe-4162; PXIe-4163; LabVIEW NXG Help. Active Participant. Options. PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIE-4144 Four Channel Source-Measure Unit (SMU) Manufacturers :NI Model(s) :PXIE-4144 Additional Information :Four Channel Source-Measure Unit (SMU) Estimated Shipping Size Dimensions: 263 × 58 × 28mm Weight:. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. Table 1. NI PXIE-4145 PXI源测量单位 PXIE-4140 PXIE-4144. 3 kg Country of Origin: United States of America. The digitizer functionality of NI SMUs is essential for capturing detailed transient characteristics of the SMU response or for characterizing device under test (DUT) behavior such as line. RAM—1 GB RAM (32-bit) or 2 GB RAM (64-bit) A screen resolution of 1,024 x 768. NI SMU的数字化仪功能对于捕获SMU详细的瞬态响应特性或表征待测设备(DUT)响应(例如线性调整率和负载调整率)至关重要。. 0 cm × 21. Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform. ni pxie-5632 ni pxie-4144 ni pxie-5162 ni pxie-7975r ni pxi-5441 ni pxi-5124 ni pxi-2533 ni pxie-6535 ni pxie-5630 ni pxie-4142 ni pxi-5122 ni pxie-6536 ni pxi-4130 ni pxie-5672 ni pxi-5406 ni pxi-2534 ni pxi-5670 ni pxi-2501 ni pxie-6537 ni pxi-4110 ni pxi-5671 ni pxi-2503 ni pxi-5402 ni pxie-5641r ni pxie-2532b ni pxie-5450• Fans set to the highest setting if the PXI Express chassis has multiple fan speed settings Device Capabilities The following table and figure illustrate the voltage and the current source and sink ranges of the PXIe-4144. PXIe-4143 National Instruments PXIe-4143 Source Measure Unit (SMU) from National Instruments | Buy Today from Artisan. Solution. 0 or later must be installed on your system prior to upgrading to Calibration Executive 5. I am trying to calculate the resolution of my PXIe-4145 4CH Precision SMU, but Figure 2 in the PXIe-4145 Spec Sheet appears to have inconsistent labels on the x-axis. 5V. The PXIe-4142 (Part Number: 782430-01) has an ideal SMU response that shields the gadget under test from undesirable transients, while accomplishing the speediest conceivable testing times and elimination of framework dependability issues because of motions. Refer to the NI. ni pxie-5632 ni pxie-4144 ni pxie-5162 ni pxie-7975r ni pxi-5441 ni pxi-5124 ni pxi-2533 ni pxie-6535 ni pxie-5630 ni pxie-4142 ni pxi-5122 ni pxie-6536 ni pxi-4130 ni pxie-5672 ni pxi-5406 ni pxi-2534 ni pxi-5670 ni pxi-2501 ni pxie-6537 ni pxi-4110 ni pxi-5671 ni pxi-2503 ni pxi-5402 ni pxie-5641r ni pxie-2532b ni pxie-5450The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. Users are. 0 cm × 13. The user can utilize this output, which gives up to 6 V and 1 A, as a complementary power supply to the. Critical to many RF and wireless applications, the simulator’s fast. Best regards,Some procedures require a PXI-4070, PXI-4071, or PXI-4072 DMM as an instrument standard; running these using a PXIe-4080, PXIe-4081, or PXIe-4082 DMM causes errors. 5. Rated 5 /5 based on 11 ratings. Ensure that the ejector handle is in the downward (unlatched) position. PRT STP IGS Product Support Resources. Getting Started with PXI Express Multifunction I/O Hardware and LabVIEW; Other Support Options Ask the NI Community. Optional Items • NI screwdriver (part number 781015-01). It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Hi, We use NI-DCPower package to communicate with PXIe-4144, PXIe-4138, etc. The PXIe‑1073 is designed for a wide range of test and measurement applications and provides an integrated MXI‑Express controller. 1/8. PXIe-4141 National Instruments PXIe-4141 Source Measure Unit (SMU) from National Instruments | Buy Today from Artisan. Search the NI Community for a solution;cal is the internal device temperature recorded by the NI 4144 at the completion of the last self-calibration. A valid service agreement may be required. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, PXIe-4145, and PXIe-4147 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXIPXIe-4144 PXIe-4145 PXI Source Measure Unit Driver. The digitizer functionality of NI SMUs is essential for capturing detailed transient characteristics of the SMU response or for characterizing device under test (DUT) behavior such as line. 500 mA Quadrant II Sink SMU Specifications Voltage. PXIE-4144 PXIE-4143 PXIE-4142 PXIE-4141 PXIE-4140 PXIE-4113 PXIE-4112 PXIE-2790 PXIE-2727 PXIE-2725 PXIE-2593 PXIE-2575 PXIE-2569 PXIE-2543. 例如,假设您在单点输出模式下使用PXIe-4139。. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. × 8. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。新しいPXI(e)リアルタイム(RT: Real Time)コントローラを購入しました。この新しいPXI(e) RTシステムのプログラミングを始めたいので、RTターゲットプログラミングを始める際のヘルプが必要です。PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXI Chassis. Buy 782432-01 - Ni - Source Measure Unit SMU, 4-Channel, 4-Quadrant, PXIe-4144, ± 500mA, ± 6V, 3W. PXIe-4144 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±6 V 10 μA 100 μA 1 mA 10 mA 100 mA 500 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (airPXIe-4496 NI module, NI, PXIe-4496 NI module Brand: General Electric Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. 2. NI PXIE-4145 PXI源测量单位 PXIE-4140 PXIE-4144. In the 10 V range, resolution can be calculated by multiplying 10 V by 100 ppm, as shown in the following equation: 10 V * 100 ppm = 10 V * 100 * 1×10 -6 = 1 mV. Timebase reference sources PXI Express 100 MHz (PXI_CLK100) Data transfers DMA, interrupts, programmed I/O, MGTs Number of DMA channels 60 Onboard DRAM Memory size 8 GB (2 banks of 4 GB) DRAM clock rate 1333 MHz Physical bus width 64 bit LabVIEW FPGA DRAM clock rate 333 MHzAs an example when the PXIe-4141 is configured as shown in Figure 1, where DUTs sharing same GND. Add to my manuals. PXIe-4144 configured for normal transient response. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. × 5. If this is your business and you notice incomplete. Before proceeding, ensure that a compatible version of NI-DCPoweris installed on the development PC. PXIe, 18-Slot (17 Hybrid Slots), Up to 4 GB/s PXI Chassis. Diversified models and products, and all kinds of rare and discontinued products 4. ni pxie-4138/4139での上級シーケンスのサポート 別のアプリケーションでの使用中にNI-DCPowerデバイスをデバッグするサポート。 NI-DCPowerソフトフロントパネルでデバイスを監視および制御して実行PXIe-4144; PXIe-4145; PXIe-4154; Non-NI-DAQmx-Based Power Supplies and SMUs. Find complete product documentation to learn how to get. The PXIe-1095 features a high-bandwidth backplane and up to 82 W of power and cooling in every slot to meet a wide range of high-performance test and measurement application needs. The PXIe-4138 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. Four-Channel SMU. 09-26-2012 01:02 PM. Device Capabilities. The fast sample rate of the PXIe-4145 can reduce measurement times. PXI Products, Created by the PXI Leader. NI-DCPower 21. This VI and all subsequent niDCPower VIs can be found in the Instrument I/O >> Instr Drivers >> NI-DCPower palette. Hi, We use NI-DCPower package to communicate with PXIe-4144, PXIe-4138, etc. • A PXI Express embedded controller or. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. CU_PXIE-4144 2X #4-40. The applicable hardware driver for specific NI modules is still required for full module functionality. PXIe-4144 Quadrant Diagram, All Channels. ranges of the PXIe-4144. Of the more than 1,500 PXI products on the market, more than 600 were designed by NI. It is automatically set by the instrument based on the current and voltage limits which the user provides as an input to the niDCPower APIs. 47 [] 5. PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 Issue Details I would like to connect multiple SMU channels in parallel, so I can increase the available amount of current. Follow the steps below to programmatically route a SMU signal to a PXI_TRIG line: Place a niDCPower Initialize With Channels VI on the Block Diagram. Refer to the NI website for an up-to-date list of known issues in NI-DCPower 17. For chassis with slot cooling capacity = 38 W, fan. ) Weight 412 g (14. First, if your device under development is a PXI type, not a PXI Express (PXIe), check this KB about PXI pinout. The AC power cord grounds the chassis and protects it from electrical damage while you install the PXIe-5413. Share. LabVIEW NXG Support and Considerations. NI-DCPower Issue Details I would like to generate a voltage or current waveform like a sine wave signal or an arbitrary waveform using a. PXIe-4144 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink RangesPXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis美国ni pxie-4144 输入输出模块 停产备件 Company advantage service: 1. Diversified models and products, and all kinds of rare and discontinued products 4. This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 2 Channels are isolated from earth ground but. When using multiple PXIe-517x NI Reconfigurable Oscilloscope cards and there is a need to synchronize them, than there are two options for the user: Using the NI-SCOPE Driver with NI-TClk for synchronization implementation - NI-SCOPE Examples. This document explains how to install, configure, and test the. Ensure maximum electromagnetic compatibility and proper system requirements are met for optimal performance. Email: info@artisantg. Related Links. use triggers and events to synchronize operations within a single NI power supply or SMU and operations with other PXI/PXI Express devices. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. Diversified models and products, and all kinds of rare and discontinued products 4. 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). cable with four-channel PXIe-414 x source measure units (SMUs). 6. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. You can use NI-DCPower to control programmable power supplies and source measure units (SMUs). Products. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit. Current Limit Range VI decides the resolution, while Current Limit VI defines limit. • Fans set to the highest setting if the PXI Express chassis has multiple fan speed settings Device Capabilities The following table and figure illustrate the voltage and the current source and sink ranges of the PXIe-4144. PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit. The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Skip to content. PXIe-4144 PXIe-4141 PXIe-4145 PXIe-4140 PXIe-4143 PXIe-4154 Driver. Voltage Programming and Measurement Accuracy/Resolution Range Resolution (noise limited). 5 GHz). Operating Environment Ambient temperature range 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. DC Current Source and Sink Ranges. It includes two processors and a real-time on-board system, and has multi axis insertion function. Also for: Ni pxie-4141, Ni pxie-4142, Ni pxie-4143, Ni pxie-4144, Ni pxie-4145. This process involves using the NI-DCPower VIs to export the SMU signal onto a PXI_TRIG line. For voltage >60 V DC and triaxial connectivity, consider the PXIe-4135 SMU with native triaxial connectors. •Voltage Range: -6 V to 6 V. Sign In Upload. 没有此功能,您将需要一个外部示波器。. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. Options. Four-Channel SMU. 2. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Many applications involve multiple types of instruments such as digitizers, signal generators, digital waveform analyzers, digital waveform generators,. Figure 2. PXIe-4144 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 3 ±6 V 10 μA 100 μA 1 mA 10 mA 100 mA 500 mA Figure 1. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. However the DCPower instruemnt drivers do not show up in LabVIEW even though they are already installed on. The PXIe-4144 has a resolution of 1,000 ppm when set to a 100 μs aperture time. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 如果. 6 cm (0. The chassis features compact, rugged packaging as well as acoustically quiet operation, which makes it ideal for both portable and. Touch any metal part of the chassis to discharge static electricity. PXIe-4144 PXIe-4141 PXIe-4145 PXIe-4143 PXIe-4140. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. PXIe-4144 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink RangesThe PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Solution. cal is the internal device temperature recorded by the NI 4144 at the completion of the last self-calibration. × 5. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Additional derating applies to module sinking power when operating at an ambient temperature of >45 C. This way you’ll save time on finding the necessary info. Read verified and trustworthy customer reviews for Pizazz Pizza Victoria or write your own. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. Industry leading, price advantage, quality assurance 3. PXI Express NI 414xモジュールは、PXI Express周辺スロット、PXI Expressハイブリッド周辺ス ロット、PXI Expressシステムタイミングスロットに取り付けることができます。 6. Manuals. For more information about theNI PXIe-4140/4141/4142/ 4143/4144/4145 Four-Channel SMU Note Before you begin, install and configure your chassis and controller. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Product Manuals: NI PXIe-4144/4145 Specifications 附加檔案: 報告日期: 04/30/2012 最後更新: 04/11/2016 文件偏號: 5WTC63PC. Is it recommended to connect the Source Measure Units in parallel? Solution It is possible to combine two SMU channels in parallel for higher current, however, this may. It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. 2では、次のバージョンのアプリケーションソフトウェア (サービスパックを含む) がサポートされています。NI InstrumentStudio 2022 Q3 Readme. 5. 821 [122. com. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. 0 cm × 21. ステップ1. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. これにより、シャーシが接地されます. This document explains how to install, configure, and test the. NI PXIe-4140/4141/4142/ 4143/4144/4145 Four-Channel SMU Note Before you begin, install and configure your chassis and controller. The capacity to accomplish an ideal. The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. NI. 0: The NI-DCPower Soft Front Panel has been replaced by InstrumentStudio, which is automatically installed when you install the NI‑DCPower driver. used. com. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit. The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. × 5. PXIe-4163 Controller module, NI, PXIe-4163 Controller module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. 要. Processor—Pentium 4 or equivalent. It also offers a Timing and Synchronization option that includes external clock and trigger routing. Created Date:PXIe-4144. •Current Range: -3 A to 3 A. TB-414X terminal block pdf manual download. The PXIe-4138 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. 美国ni pxie-4144 输入输出模块 停产备件 Company advantage service: 1. PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 问题详述 我想并行连接多个SMU通道,所以我可以增加可用电流量。是否建议将源测量单元并联? 解决方案. 3 Vのレールか ら350 mA 環境 The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Has been engaged in industrial control industry for a long time, with a large number of inventories. 99 oz) Front panel connectors 25-position D-SUB, male Power Requirement PXI Express power requirement 600 mA from the 12 V rail and 350 mA from the 3. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. Industry leading, price advantage, quality assurance 3. Windows Server 2016 64-bit. 外形寸法 3U、1スロット、PXI Express/CompactPCI Expressモジュール 2. 15 days free replacement. These modules can measure an analog voltage up to 42 V when using the TB-4304. ) Weight 425 g (14. NI-DCPower package, sample rate. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 6. 2D Dimensional Drawings. 5 in. This page provides dimensional drawings for the PXIe-4144. PXIe-5172 Data acquisition card, NI, PXIe-5172 Data acquisition card Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. 500 mA I– Limit power sinking to 7 W per module. Call the niDCPower Get Self Cal Last Temp VI to query Tcal from the NI 4144. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Table 1. Click here to sell your equipment! •Number of SMU Channels: 1 •Voltage Range: -60 V to 60 V •Current Range: -3 A to 3 A •Current Sesitivity: 1 pA •Source Adapt: No Part Number: 782856-01 Please contact Artisan Technology Group Sales for configuration pricing and availability. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. All other SMUs will have a non-zero current which will be sinked in the SMU. The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Fax: (240) 376-1381. 2. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. MeetsThe PXIe‑4340 is a filtered analog input module for AC linear variable differential transformer (LVDT), AC rotary variable differential transformer (RVDT), resolver, and synchro measurements. Quick quote: NI PXIe-4144 +1 800. Part Number: 781743-01, 150660B-02L. 2. The NI PXIe-4140 has 4 quadrants; each channel has integrated remote sensing (4 wires) for precise estimations. Refer to ni. NI PXIe-4144. 5 in. PXIE-4357 NI module, NI, PXIE-4357 NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. tel: 250-727-3721. fax: website: employees: ~ 3 employees work at this location. The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. •Voltage Range: -10 V to 10 V. 153697C-01L 782432-01 NI PXIE-4144 4-CHANNEL SMU: 6V, 500MA 153697C-02L 782435-01 NI PXIE-4145 4-CHANNEL PRECISION SMU: 6V, 500MA Contact Information Please do not reply to this email. Restricted Item . The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. Set Output to ON. •Voltage Range: -24 V to 24 V. Has been engaged in industrial control industry for a long time, with a large number of inventories. The PXIe-4141 has a resolution of 100 ppm when set to a 100 μs aperture time. The PXIe-4145 by National Instruments is In Stock & Ready to Ship at Apex Waves. 148 3. Industry leading, price advantage, quality assurance 3. System RequirementsThis document contains specifications for the PXIe-1071 chassis. PXIe-4144. Click to Contact Seller. vi in order to regulate aperture time. LabVIEW. 3 A The following figure illustrates the voltage and the current source and sink ranges of the PXIe-4147. NI PXIe-4144 (782432-01) Datasheet Datasheet 306. For example Ch0 can sink current from Ch2, but as all channels are configured in source mode then this is not correct working regime for the device, which can cause the damage of the channel. . 153697-01L. The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 15 days free replacement. com | NI PXIe-4144 Calibration ProcedureTerminal Block. Search for used 4144. PXIE-4141 Data acquisition card, NI, PXIE-4141 Data acquisition card Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. 15 days free replacement for quality problemsNational Instruments PXIe-4145 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 4. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4145. 8. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。 pxie-4144 是一款 4 通道電源量測單元 (smu) ,非常適合多引腳應用。 其提供 4 象限作業,各個通道均整合遠端 (四線式) 感測,可執行準確的量測作業。 高取樣率的 PXIe-4144 能夠縮短量測時間、擷取瞬變裝置特性化,並迅速取得受測裝置 (DUT) 的 I-V 特性化。 PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. NI PXIe-4140/4141/4142/ 4143/4144/4145 Four-Channel SMU Note Before you begin, install and configure your chassis and controller. the PXIe-4144. Additional derating applies to module sinking power when operating at an ambient temperature of >45 °C. Related Information Sinking Power vs. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V. •Current Sesitivity: 100 pA. Hardware: PXI/CompactPCI>>Chassis>>PXIe-1082 cDAQ-9174 Data acquisition card. Configuration: •Number of SMU Channels: 4. PXIe-4144. It supports accurate measurement up to 30V / 500mA with resolution down to 6μV / 100pA. The chassis features compact, rugged packaging as well as acoustically quiet operation, which makes it ideal for both portable and desktop systems. Please contact Artisan Technology Group Sales for configuration pricing and availability. Industry leading, price advantage, quality assurance 3. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisNI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 3. The PXIe-4143 (Part Number: 782431-01) Source Measure Unit (SMU) incorporates a utility channel that can supply current or voltage with a 16-bit setpoint and an estimation resolution. When taking a measure record, only the Aperture Time property affects the sampling rate. PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. View and Download National Instruments PXIe-4138 calibration procedure online. PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 Issue Details I would like to connect multiple SMU channels in parallel, so I can increase the available amount of current. DC Current. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Table 1. Important Notice: Other accessories, manuals, cables, calibration.